Hi, hardly ever check this newsgroup anymore. I don't know the particular caps that need replacing, but if it were me I would change all the capacitors to the righthand side of the yellow transformer in the middle. I can see 10 cap's to change (unless one is hiding under the ribbon cable) There pretty cheap, don't worry about values too much if you can't get the exact value get the next     

Group: aus.tv.digital · Group Profile · Search for Crystalsinger in aus.tv.digital
Author: Damon
Date: Jun 13, 2008 19:44

Damon Wrote: Common fault, capacitors C15 and C16 fail on the Power Supply Board. Strong in Melbourne will fix it for free or you can change them yourself if you are competent with a soldering iron. They should be replaced with 220uF 25V 105C low ESR capacitors that are available from Altronics or Jaycar. Don't use Dick Smith ones or it will be broken again in weeks
Show full article (1.93Kb) · Show article thread
    

Group: aus.tv.digital · Group Profile · Search for Crystalsinger in aus.tv.digital
Author: crystalsinger
Date: Jun 11, 2008 22:27

Show full article (1.23Kb)